SWP1
SWP1-16MMF | SWP1-8MMF | SWP1-8 | ||
---|---|---|---|---|
Number of LAN ports (1000BASE-T/100BASE-TX/10BASE-T, etherCON connector) | 12 | 8 | 8 | |
Number of LAN ports (1000BASE-T/100BASE-TX/10BASE-T, RJ-45 connector) | 4 | - | - | |
Number of SFP ports (1000BASE-SX, opticalCON connector) | 2 (1 optical module is installed as standard) | 2 (1 optical module is installed as standard) | 2 (optical modules are not installed as standard) | |
Console port | 1 (RJ-45) | 1 (RJ-45) | 1 (RJ-45) | |
Automatic negotiation | Available | Available | Available | |
Auto MDI/MDI-X | Available | Available | Available | |
Switching capacity | 36 Gbit/s | 20 Gbit/s | 20 Gbit/s | |
Throughput | 27 Mpps | 15 Mpps | 15 Mpps | |
Maximum number of MAC addresses | 16,384 | 16,384 | 16,384 | |
Frame buffer | 1024 kB | 1024 kB | 1024 kB | |
VLAN | Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN | Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN | Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN | |
Maximum number of VLANs | 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. | 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. | 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. | |
IP multicast | IGMP Snooping (v1/v2/v3) | IGMP Snooping (v1/v2/v3) | IGMP Snooping (v1/v2/v3) | |
QoS | 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) | 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) | 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) | |
Flow control | IEEE802.3x (Full-duplex), back pressure (Half-duplex) | IEEE802.3x (Full-duplex), back pressure (Half-duplex) | IEEE802.3x (Full-duplex), back pressure (Half-duplex) | |
Support functions | Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. | Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. | Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. | |
DIP switches | CONFIG, VLAN PRESET | CONFIG, VLAN PRESET | CONFIG, VLAN PRESET | |
指示燈 | Front: POWER, LED MODE×4, PORT×16×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. | Front: POWER, LED MODE×4, PORT×8×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. | Front: POWER, LED MODE×4, PORT×8×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. | |
作業溫度 | 0 to 40°C | 0 to 40°C | 0 to 40°C | |
存儲溫度 | -20 to 60°C | -20 to 60°C | -20 to 60°C | |
Power supply (AC IN inlet) | AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type | AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type | AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type | |
Power supply (EXT DC INPUT inlet) | External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector | External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector | External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector | |
最大功耗 | 16 W, 0.29 A | 11 W, 0.21 A | 11 W, 0.21 A | |
散熱 | 14.0 kcal/h | 9.5 kcal/h | 9.5 kcal/h | |
Chassis | Metal case, no fan | Metal case, no fan | Metal case, no fan | |
有害物質管理 | RoHS compliant | RoHS compliant | RoHS compliant | |
體積 | 寬 | 480mm | 480mm | 480mm |
高 | 44mm | 44mm | 44mm | |
尺寸 | 深 | 362mm | 362mm | 362mm |
重量 | 4.6 kg | 4.2 kg | 4.2 kg | |
配件 | Power cord, Owner's manual | Power cord, Owner's manual | Power cord, Owner's manual | |
選項 | MMF-SWP1 (Optical expansion unit), PA-700 (AC adaptor) | MMF-SWP1 (Optical expansion unit), PA-700 (AC adaptor) | MMF-SWP1 (Optical expansion unit), PA-700 (AC adaptor) |
INTERFACE SPECIFICATIONS
*1 SWP1-8MMF, SWP1-8
*2 SWP1-16MMF
*3 These terminals support AutoMDI/MDI-X
*4 The SWP1-8MMF supports the option for port 10, and the SWP1-8 supports the option for both ports 9 and 10
*5 The SWP1-16MMF supports the option for port 18
*6 For the pin assignments, refer to CONNECTOR PIN ASSIGNMENTS
*7 Pin 4=+24VDC, pin 1=GND, pins 2 and 3=N.C.
External power supply requirements: 24VDC±2V, 1A
*8 Conforming cable: GI-type multi-mode fiber cables with a core diameter /cladding diameter of approximately 50 μm/125 μm.
Maximum cable length: 300 m
CONNECTOR PIN ASSIGNMENTS
CONSOLE (RS-232C)
*9 These ports are not used on the SWP1.
Dante Mode & VLAN Preset Settings
Common Settings to Dante Mode
- QoS (Quality of Service)
- Enabled
- QoS Trust Mode
- DSCP
- DSCP to Queue (*1)
- DSCP:56 -> 7, DSCP:46 -> 5, DSCP: 8 -> 2, Others -> 0
- EEE (Energy Efficient Ethernet)
- Disabled
Preset Normal
- Ports 1 to 8 (1 to 16)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 9/10 (17/18)
- Access Port, VLAN 1, LAG On (sa1), STP On (*2), Loop Detection Off
- VLAN 1 (for Dante)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
Preset A
- Ports 1/2, 5/6 (1 to 6, 9/10, 13/14)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 3/4, 7/8 (7/8, 11/12, 15/16)
- Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
- Ports 9/10 (17/18)
- Trunk Port, VLAN 1/2, LAG On (sa1), STP On (*2), Loop Detection Off
- VLAN 1 (for Dante)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
- VLAN 2 (for Others)
- IGMP Snooping: Disabled
Preset B
- Ports 1/2, 5 (1 to 6, 9/10, 13)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 3/4, 6 (7/8, 11/12, 14)
- Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
- Ports 7 to 8 (15 to 16)
- Trunk Port, VLAN 1/2, LAG On (sa1), STP On (*2), Loop Detection Off
- Ports 9 to 10 (17 to 18)
- Trunk Port, VLAN 1/2, LAG On (sa2), STP On (*2), Loop Detection Off
- VLAN 1 (for Dante)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
- VLAN 2 (for Others)
- IGMP Snooping: Disabled
Preset C
- Ports 1/2, 5/6, 9 (1 to 6, 9/10, 13/14)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 3/4, 7/8, 10 (7/8, 11/12, 15/16)
- Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
- VLAN 1 (for Dante Primary)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
- VLAN 2 (for Dante Secondary)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IGMP Snooping: Enabled
* The port numbers in parentheses refer to those on SWP1-16MMF.
*1 The DSCP to Queue settings are optimized for Dante.
*2 In order to activate Spanning Tree protocol (MSTP), you need to turn off Link Aggregation on the corresponding ports. You can download the Config files with Spanning Tree enabled here.