RIVAGE PM Firmware V6.01 (Previous version)

Important Notice

Problem with Dynamics parameters when loading setup file

A problem has been found in RIVAGE PM V6.01 where Channel Dynamics parameters in the console’s current state may be changed in RIVAGE PM V6.01 when a console setting file created in firmware prior to V5 is loaded into V6.01. This could happen regardless of Recall Safe and Focus Recall settings.

Temporary workaround

Open the original file in RIVAGE PM Editor V5.1.4 and store the current Scene to a new Scene number, then re-store the file.
Next, load the newly stored file into a RIVAGE PM system or RIVAGE PM Editor running V6. Ensure that Recall Safe settings of all Channel Dynamics are disabled, and Focus Recall for the Scene stored in the previous step includes the Channel Dynamics. Recall that Scene and re-save the file in that state.
The file will now load correctly with a V6 system.

Problem with HY Slot1 hosting HY144-D, HY144-D-SRC cards

A problem has been found in RIVAGE PM V6.01 in which, when either HY144-D or HY144-D-SRC cards are inserted in HY Slot1 and multiple Dante I/O devices such as Rio-D2/D are mounted, control of HA gain, patch settings, etc. may become impossible.

Temporary workaround

For RIVAGE PM V6.01, insert HY144-D and HY144-D-SRC cards into slots other than HY Slot1.

RIVAGE PM Firmware / Editor / StageMix Compatibility

Follow the version compatibility chart in the link below to make sure that all firmware versions are compatible with CS-R10, CS-R10-S, CSD-R7, CS-R5, CS-R3, DSP-R10, DSP-RX, DSP-RX-EX, RPio622, RPio222, RIVAGE PM Editor, RIVAGE PM StageMix, and MonitorMix when you operate the RIVAGE PM system. Using an unsupported Editor/firmware combination may result in unexpected behavior.

For TWINLANe network cards to be updated simultaneously with their host device (HY256-TL, HY256-TL-SMF), install them into a corresponding slot. If any additional cards are installed after performing the update, please execute the update program again.
To update a Dante card (HY144-D, HY144-D-SRC), use the Dante Firmware Update Manager or the Dante Updater of Dante Controller.

RIVAGE PM/CL/QL/R/Tio Compatibility

Dante I/O Supported device information

New features in V6.01

  • Genius.lab* functionality has been added.
    * Genius.lab is a functionality that allows you to freely set up a sequence of actions (= macros) to be executed when certain conditions are met.
  • Interphase* plug-in has been added.
    *Interphase is a plug-in that adjusts the time and polarity between two channels using Delay, Polarity, and an All-Pass filter. By adjusting these parameters, the two channels can be time and polarity aligned.
  • FET LIMITER and DIODE BRIDGE compressor options have been added to Channel DYNAMICS types.
  • A MIX BALANCE parameter has been added to all channel DYNAMICS types.
  • DM3, DM7/DM7 Compact, DME7, and Tio1608-D2 have been added to the SUPPORTED DEVICE list in the DANTE DEVICE SELECT pop-up screen.
  • A mode has been added to Store and Recall CUSTOM FADER LAYER channel assignments with Scenes.
  • The NOMINAL POSITION of PAN can now be selected between LR NOMINAL and CENTER NOMINAL.
  • A PHASE reverse switch has been added to all MIX buses, MATRIX buses, and STEREO buses.
  • Output load impedance of OMNI OUT and RY16-DA can now be selected from 600Ω and 10kΩ.

Improvements and Changes in V6.01

  • Improved behavior regarding synchronization of BPM and tap tempo of plug-ins.
  • A PHONES LEVEL LINK button has been added to the MONITOR SETTING pop-up screen.
  • When a USER DEFINED key is used to enter the SENDS ON FADER mode to a specified bus, the mix select pop-up screen will no longer open.
  • Word clock leader indication for the DSP icon has been added on the SYSTEM screen.
  • In THEATRE MODE, the state of the CH ON FOLLOWS DCA ASSIGN setting now remains in place following a power cycle.
  • Changed the display on the OVERVIEW screen and DYNAMICS1/2 pop-up screens (CH 1-72, CH73-144, MIX, MTRX/ST) to show dynamics on/off status.
  • The output port on the OUTPUT tab of the DANTE PATCH pop-up screen now displays the name of the channel being patched.
  • RY cards that do not have an INPUT PORT cannot be set to TWINLANe assignment ON.
  • Plug-in parameters can now be changed by touch-and-drag on screen.
  • Fader Banks to be displayed in RIVAGE PM Editor can now be assigned for Recall Safe/Focus Recall and Global Paste.

Fixed bugs in V6.01

  • Fixed a problem in which DANTE PATCH could be changed when loading a settings file, even though the DANTE PATCH (NAME) BY - DANTE CONTROLLER was selected.
  • Fixed a problem that caused a DANTE DEVICE to remain Virtual in certain rare cases when a settings file was loaded.
  • Fixed a problem in which, in a system with multiple DSP engines, the TWINLANe network assignment might be removed when one of the DSP engines was restarted.
  • Fixed a problem in which the lowest event in the event list was executed if there was a glitch (discontinuity) in timecode into the system.
  • Fixed a bug that caused faders to move incorrectly in rare cases when switching fader layers on the CS-R3.
  • Fixed a problem in which the global pasting of stereo input channels would cause the L-ISA-related parameters of the L channel to be copied over to the R channel and become identical.
  • Fixed a problem in which the network or connected device status of a card mounted in the HY slot was incorrectly displayed as an error in rare cases during system startup.
  • Fixed a problem that caused an incorrect Cooling Fan State:[Error] log entry to be generated as the system was turned off.
  • Fixed a problem in which PROGRAM CHANGE was output from the MIDI OUT of the console when a scene was recalled in PREVIEW mode.
  • Fixed a problem with the RIVAGE PM Editor in which the BAY MODE setting for CUE A/B was not reflected in the SELECTED CHANNEL VIEW.
  • Fixed a problem, on CS-R3 only, in which pressing the HOME key when nothing is bookmarked to the key caused the currently selected channel to be unselected, and the system might then be forced to restart when displaying the EQ pop-up screen in this state.
  • Fixed a problem where one type of Output Bus could be wrongly copied to a different type of Output Bus by using the COPY & PASTE keys on the console’s top panel.

Known issues

  • Activating the LEARN function of the DaNSe plug-in may lead to a delay in processing audio parameters that are edited during the processing of the LEARN function itself in V6.01. The result of LEARN may also take longer than usual to be applied. This will be fixed in a future update.
  • The gain metering function of the Dugan Automixer is not operating correctly in V6.01, although the actual performance of the automixer is correct. This will be fixed in a future update.
  • The FET LIMITER does not operate correctly when used on stereo channels numbered in multiples of 6 (channels 6+7, 12+13, 18+19 and so on.) in V6.01.
    This will cause distortion on those channels. This will be fixed in a future update.

Notices in version updating

  • When updating CS-R5 from V4.00, the touch panels may not respond when the update is completed. If this happens, skip the proper shutdown procedure and turn the power switches off and back on again. The console will operate normally once correctly updated to V5.00.
  • When updating console or DSP firmware, the progress bar may stop or the update may close with an error. If this continues for 10 minutes or longer, turn the power to the device off and on, and then retry the firmware update.
  • It is not possible to update DSP-RX(-EX) when using DSP Mirroring and the engine is in ‘Standby’ state. Please set DSP-RX(-EX) to ‘Active’ state and then proceed with the update.
  • The project file saving method has been changed from V1.20.
    When loading a project file saved by V1.16 or earlier, the patching of plug-ins may be unintentionally removed. If this happens, manually patch them again.
  • When loading a project file saved by V1.21 and earlier, the RACK Focus status indicator on the SCENE screen may not light even if effect plug-ins or GEQs are the target of Focus Recall. To indicate the Focus status properly, open the SCENE SETUP (FOCUS) pop-up screen once, and then close it. After doing this, save the revised project file to remove this problem in the future.

Notices in version downgrading

  • Do not load a project file saved by V1.51 and later to a system running V1.21 and earlier. When loading, all plug-ins will be un-mounted in all Scenes including the current memory. In this case, re-mounting and setting up of parameters will be required.
  • When downgrading the firmware, be sure to initialize all systems after downgrading.
  • When loading data including the MixToInput settings of the V3.00 system, the MixToInput function will work in RIVAGE PM systems even of less than V3.00. However, be careful of the possibility of unwanted signal loops, etc.

Notices for usage

  • The RIVAGE PM can only play back MP3 and WAV files whose file name is no longer than 60 single-byte characters or 20 double-byte characters excluding the extension. Please note that a file name exceeding this limit will not appear in the list on the RECORDER window.
  • An error dialog “Console Network ring connection open! Check cable connection.” may rarely be displayed when the sampling rate is changed on the WORD CLOCK screen. However, it does not affect the actual operation.
  • When INPUT patching is performed with the maximum number of channels of the HY256-TL or HY256-TL-SMF card exceeding 256, it appears to be correctly patched but no patch is established and no audio is input.
  • In rare cases, a “DSP Disconnected!” message could be shown. If the message appears, take the following course of action:
    1. Re-Sync manually. Check this first for the fastest possible recovery (Doesn’t apply to RIVAGE PM7).
    2. If that doesn’t solve the problem, use the [RESET] button on the back of the console (Operations 1 and 2 do not mute the audio).
    3. If that doesn’t solve the problem, restart the console.
    4. If that doesn’t solve the problem, restart the DSP Engine (Doesn’t apply to RIVAGE PM7) (Operations 3 and 4 mute the audio).
  • If you recall a Scene in which a very high HA gain was set, from a scene having a low HA gain, even if no signal is patched, a very loud pink noise signal is occasionally output for a few seconds.
  • When a certain type of USB keyboard is connected to the console, the following message may appear:
    You must restart your computer to apply these changes [Restart Now] [Restart Later]
    If this message is shown, remove this USB keyboard. It is not compatible with the console and cannot be used. The console does not need to be restarted.
  • When a DSP mirroring failover occurs and the DSP engine B is set to active while the DSP engine A is the word clock leader and is still powered on, the Word Clock leader will not change automatically. To prevent audio dropouts, do not turn off the power of the DSP engine A even after a failover occurs.
  • The channel name LCD cannot display unsupported characters such as Japanese kanji used in the Dante channel labels.
  • If there are multiple DSPs in the same TWINLANe ring, or multiple HY144-D or HY144-D-SRC cards in the same Dante network in one DSP, only one of the cards should be enabled for SYNC TO EXTERNAL and that card should be set as the PTP LEADER.
  • The Dante Domain Manager (DDM) SMPTE flow is displayed as AES67 to patch. There is no problem in the actual operation.

注意

使用此軟體前,請仔細閱讀軟體授權協議(「協議」)。您僅可依據此協議的條款和條件使用此軟體。此為您(個人或法律實體)和 YAMAHA CORPORATION(「YAMAHA」)間簽署的協議。 

下載或安裝此軟體或以其他方式供您使用,您同意接受此授權條款的約束。如果您不同意此條款,請勿下載、安裝、複製或以其他方式使用此軟體。如果您下載或安裝軟體但不同意條款,請立即刪除軟體。

授權授予和版權

Yamaha 特此授予您依據隨附條款和條件,在您擁有或管理的電腦、樂器或設備上使用程式和隨附此協議並構成軟體一部分的資料檔案,以及未來可能提供您進行軟體升級的任何程式和檔案(統稱「軟體」)的權利。雖然儲存軟體的所有權為您所有,但該軟體本身屬於 Yamaha 和/或 Yamaha 的授權方所有,並受相關版權法和所有適用法規的保護。

限制

  • 您不得 從事反向工程、反彙編、反編譯或以任何方式取得軟體任何形式的程式碼。
  • 您不得 重製、修改、變更、租賃、出租或散布完整或部分軟體,以製作軟體的衍生品。
  • 您不得 以電子方式,從一台電腦傳輸軟體至另一台電腦,或在網路上與其他電腦共用軟體。
  • 您不得 使用軟體,散布非法資料或違反公共政策的資料。
  • 在未取得 Yamaha Corporation 的同意時,您不得依據軟體的使用,啟動服務。

透過軟體方式取得的版權保護資料,包含但不限於樂曲 MIDI 資料,有您必須遵守的以下限制條款。

  • 在未取得版權所有人的同意時,不得將透過軟體方式接收的資料作為商業用途使用。
  • 在未取得版權所有人的同意時,不得複製、傳輸或散布或為公開聽眾播放或表演透過軟體方式接收的資料。
  • 在未取得版權所有人的同意時,不得移除透過軟體方式接收資料的加密,且不得修改電子浮水印。

終止

如果違反版權法或此協議條款,協議將自動立即終止,Yamaha 恕不通知。如果以此方式終止,您必須立即銷毀授權的軟體、隨附的書面文件和所有副本。

下載的軟體

如果您認為下載流程有問題,可聯絡 Yamaha,Yamaha 可允許您重新下載該軟體,前提是您需先銷毀透過先前下載嘗試取得的軟體的任何副本或部分副本。重新下載的許可不得以任何方式限制以下第 5 節所述保固聲明。

軟體保固聲明

您明示已同意自負使用軟體的風險。軟體和相關文件以「原狀」提供,且無任何保固。儘管本協議另行規定,YAMAHA 明示放棄軟體的所有明示和暗示保固,包括但不限於對適銷性、特定用途的適用性和不侵犯第三方權利的暗示保固。特別是,但不限制上述規定,YAMAHA 不保證軟體滿足您的要求、軟體的操作不會中斷或沒有錯誤或軟體的缺失得以修正。

責任限制

YAMAHA 的全部義務是根據以下條款允許使用本軟體。在任何情況下,對您或任何其他人遭受的任何損害,包括但不限於任何直接、間接、偶然或間接損害、費用、利潤損失、資料遺失或其他因使用而造成的損害、誤用或無法使用該軟體,即使 YAMAHA 或授權經銷商已被告知此類損害的可能性,YAMAHA 概不負責。在任何情況下,Yamaha 對您的所有損害、損失和訴訟原因(無論是合約、侵權或其他方式)的全部責任均不超過為該軟體支付的金額。

第三方軟體

此軟體隨附第三方軟體和資料(「第三方軟體」)。如果軟體隨附的書面材料或電子資料中,Yamaha 將任何軟體和資料標示為第三方軟體,則您確認並同意您必須遵守第三方軟體隨附的任何協議條款以及提供第三方軟體的一方,對與第三方軟體相關或由第三方軟體衍生的任何保證或責任負責。因第三方軟體或使用,Yamaha 概不以任何方式負責。

  • Yamaha 不提供第三方軟體的明示保固。此外,對於第三方軟體,YAMAHA 明示放棄所有暗示保固,包括但不限於對適銷性和特定用途的適用性的暗示保固。
  • Yamaha 不應提供您第三方軟體的相關服務或維護。
  • 對您或任何其他人的任何損害,包括但不限於因使用、誤用或無法使用第三方軟體而導致的任何直接、間接、偶然或後果性損害、費用、利潤損失、資料遺失或其他損害,對您或任何其他人,Yamaha 概不負責。

美國政府限制權利通知:

該軟體是「商業項目」,該術語的定義可見 48 C.F.R. 2.101(1995 年 10 月),由「商業電腦軟體」和「商業電腦軟體文件」組成,這些術語在 48 C.F.R. 12.212 使用(1995 年 9 月)。與 48 C.F.R.一致的 12.212 和 48 C.F.R. 227.7202-1 至 227.72024(1995 年 6 月),所有美國政府最終使用者均應僅以此處規定的權利取得本軟體。

總則

此協議應根據日本法律解釋,不受法律衝突原則的約束。任何爭議或訴訟程序應在日本東京地方法院審理。如果因任何原因,具司法管轄權的法院認定本協議的任何部分無法執行,則本協議的其餘部分仍將維持其完整效力。

完整協議

本協議構成雙方間有關軟體使用和任何隨附書面材料的完整協議,並取代所有先前或同時就本協議達成的書面或口頭理解或協議。除非經 Yamaha 的完全授權代表書面簽字,否則本協議的任何修訂或修正均不具有約束力。


您還需要