RIVAGE PM Firmware V4.13 (Previous version)

A problem was found in V4.02 or later firmware, in which a combination of specific operations will cause the LCD touch screen(s) to become inoperable and display the following error message “Software exception has been detected. PLEASE RESTART THIS CONSOLE AS SOON AS POSSIBLE.”.

Applicable Devices

CS-R10, CS-R10-S, CSD-R7, CS-R5, CS-R3

Conditions of Occurrence

Simultaneous operation of the following actions -

  • Touching and dragging across the screen to select multiple channels on the "1-72", "73-144", "145-216", or "217-288" tab for EQ or DYNAMICS.
  • Switching layers or banks, or switching windows by operation from USER DEFINED KEY, GPI, or MIDI.

Symptoms

The following symptoms may occur immediately or a few seconds after performing the above operations.

The faders, knobs, keys, and LCD touch screens on the front panel become inoperable, and the above error message appears in a few seconds. Touching the "OK" button at the bottom of the message will restore the fader, knob, and key operations. However, the LCD touch screen remains inoperable.

In this state, the system can be operated from the RIVAGE PM Editor and the sound will continue to output without any interruption.

Suggested Actions

Should this problem occur, please press the RESET button on the rear panel of the console. While it resets, the console to be inoperable for up to one minute, but sound will continue to be processed and output.

RIVAGE PM Firmware / Editor / StageMix Compatibility

Please make sure that all firmware versions match for CS-R10, CS-R10-S, CSD-R7, CS-R5, CS-R3, DSP-R10, DSP-RX, DSP-RX-EX, RPio622, RPio222, RIVAGE PM Editor, RIVAGE PM StageMix, and MonitorMix when you operate the RIVAGE PM system. Using an unsupported Editor/firmware combination may result in unexpected behavior.

For TWINLANe network cards to be updated simultaneously with their host device (HY256-TL, HY256-TL-SMF), install them into a corresponding slot. If any additional cards are installed after performing the update, please execute the update program again.
To update a Dante card (HY144-D, HY144-D-SRC), use the Dante Firmware Update Manager.

RIVAGE PM/CL/QL/R/Tio Compatibility

V4.12 is no longer available for download, because it cannot support a modified production process for CS-R5. Please use V4.13 instead.

Changes in V4.13

  • Adds support for a modified production process for CS-R5. It doesn’t provide any new features.

New features in V4.12

  • Now supports CS-R3 control surface.
  • Now supports DSP "Parameter Mirror" mode which synchronizes parameters between two DSP engines for systems that do not use TWINLANe.

NOTE

  • Switching the active DSP engine state while running parameter mirroring causes a very short interruption to sound output from an attached control surface.
  • SURFACE SETTINGS banks can now be assigned to USER DEFINED keys.
  • Added the ON button on the INSERT screen.
  • For details, refer to the RIVAGE PM series operation manual.

New features in V4.02

  • Now supports the CS-R5 control surface and the DSP-RX(-EX) DSP engines.
  • RIVAGE PM7 system Input channel count increased from 120 to 144 and Matrix channel count increased from 24 to 36.
  • Added the new Reverb Plug-in “Eventide SP2016”.
  • Added support for remote control from “MonitorMix” app (V1.3 or later) for iOS or Android.
  • Added improved flexibility of HY slots -
    • HY144-D, HY144-D-SRC and HY128-MD cards can now be used in any HY slot of all DSP engines (including CSD-R7)
    • Up to 48 Dante devices can now be mounted and controlled from a DSP Engine hosting two or more HY cards featuring Dante.

NOTE

When using two or more HY144-D/HY144-D-SRC cards in the same DSP engine, it is recommended to connect them both to the same Dante network. To remotely control HA of devices in different Dante networks via multiple HY-Dante cards, specify a unique subnet (network address) to each Dante network.

Make sure that all Dante Control IDs of HY144-D/HY144-D-SRC cards (including those inserted in the same DSP engine), and CL/QL series CONSOLE IDs that are connected to the same network, are unique (or switched OFF).

  • Improved operability -
    • Expanded custom fader bank capacity to 5 banks (which allows 30 custom layers per fader bay).
    • EQ screen frequency response graph view can now be visually expanded and multi-touch operation can be used (Only applies to CS-R5 and CS-R3).
    • In the SELECTED CHANNEL VIEW screen, EQ, DYNAMICS, and SEND parameters can now be controlled by the 12 encoders below the screen.
    • The order of DYNAMICS parameters has been improved, so OUTGAIN, ATTACK and RELEASE are found in logical positions, for example.
    • You can now move to the EDIT screen for the corresponding function by pressing an encoder in the Selected Channel section of the panel.
    • Added AUTO A.G./D.G. Function to channel strip encoders.
    • It is now possible to switch SEND blocks on the Overview screen and the SEND FROM/TO screen.
    • In addition, the screen layout has been updated.
  • Improved visibility
    • Expanded the meter area and increased resolution.
    • Expanded the channel name area.
  • Improved maintenance features
    • Expanded the LOG function.
    • The status of the entire system can now be monitored using the SYSTEM CONFIG screen.
  • Inserts via the TWINLANe network are now available for all channels.
  • Bay Link operation has been improved with more options in the SURFACE SETTINGS Preferences menu.
  • The file name extension for all console files has been changed to ".RIVAGEPM".
  • In Surround Mode, the option USE PHONES B FOR SURROUND MONITOR has been added.
  • Rupert Neve Designs RMP-D8, Focusrite Rednet 4/MP8R, and Yamaha Tio1608-D devices can now be remote controlled via the Dante network.
  • Added support for L-ACOUSTICS "L-ISA" desk link function.

For details, refer to the RIVAGE PM series operation manual.

Version 4 or newer for DSP-R10 contains software produced by a third party.

For information about the license, refer to *** (product name)_OSSLicense_e.pdf, which is included in the downloaded file.

Fixed Bugs in V4.12

  • Solved some minor errors.

Fixed Bugs in V4.02

  • Solved a problem in which the current event number in the event list may not be retained when the power was turned on for RIVAGE PM10/PM7.

Limitations

If the timecode is restarted with a valid TIME CODE SOURCE selected, the timecode value will be reset to 0 after the restart, and the event list will return to the beginning.

  • Solved a problem that channel colors were not correctly displayed when recalling a scene with changed channel colors.
  • Solved a problem in which the wrong scene title and number may be displayed in the SCENE MEMORY LCD after the [INC] key or [DEC] key was rapidly pressed multiple times.
  • Solved the problem in which, after exiting the Preview mode, a different scene number would flash in the SCENE field and the SCENE field would not show the current scene number.
  • Solved the problem in which Dante I/O devices that were mounted by selecting from -ONLINE- DEVICE LIST may not become connected but be indicated as "Virtual."
  • Solved the problem in which all the port names could not be obtained for a Dante device with 33 or more inputs/outputs that was mounted to HY144-D/HY144-D-SRC.
  • Solved some other minor errors.

Known Issues

  • With V4.02 and V4.12 of DSP-RX(-EX) and CSD-R7, the device may need to be restarted if control of L-ACOUSTICS Immersive Sound System “L-ISA” is enabled. Do not turn on the “L-ISA” button in the IMMERSIVE SOUND tab of the NETWORK screen. Should this problem occur, please follow these steps - reconfigure the DSP's ID, restart the DSP and synchronize in the direction from the console to the DSP.
  • When DSP MIRROR MODE1: TWINLANe MIRROR is used, and HY card slot 2 of RPio is set to ROUTING MODE2, output patches of HY card slot 2 are not taken over automatically by a changeover from A (active DSP) to B (standby DSP).

The workaround is the following.

  • Manually Switch the unit B to the active state.
  • Set the same patch to unit B.
  • Switch unit A back to the active state.
  • MIDI NOTE ON/OFF may not be transmitted correctly if the MIDI Note ON is assigned to a User Defined Key and is rapidly pressed several times.

Notices in version updating

  • When updating CS-R5 from V4.00, first update to V4.02 and then update to V4.12. If CS-R5 is updated directly to V4.12, the touch panels will not respond when the update is completed. If this happens, skip the proper shutdown procedure and turn the power switches off and back on again. The console will operate normally once correctly updated to the V4.12.
  • When updating CS-R5 or DSP-RX(-EX) from V4.00 or V4.02, the progress bar may stop or an error may prevent the updating process. If this continues for ten minutes or longer, turn the power off and on again, then re-start the firmware update.
  • It is not possible to update DSP-RX(-EX) when using DSP Mirroring and the engine is in ‘Standby’ state. Please set DSP-RX(-EX) to ‘Active’ state and then proceed with the update.
  • The project file saving method has been changed from V1.20.
    When loading a project file saved by V1.16 or earlier, the patching of plug-ins may be unintentionally removed. If this happens, manually patch them again.
  • When updating the console’s firmware from V1.20 or earlier, the progress bar may stop at the 14/18 status, or an error may stop the updating process. If this continues for five minutes or longer, turn the power of the console to off and on, and then retry the firmware update.
  • When loading a project file saved by V1.21 and earlier, the RACK Focus status indicator on the SCENE screen may not light even if effect plug-ins or GEQs are the target of Focus Recall. To indicate the Focus status properly, open the SCENE SETUP (FOCUS) pop-up screen once, and then close it. After doing this, save the revised project file to remove this problem in the future.

Notices in version downgrading

  • Do not load a project file saved by V1.51 and later to a system running V1.21 and earlier. When loading, all plug-ins will be un-mounted in all Scenes including the current memory. In this case, re-mounting and setting up of parameters will be required.
  • When downgrading the firmware, be sure to initialize all systems after downgrading.
  • When loading data including the MixToInput settings of the V3.00 system, the MixToInput function will work in RIVAGE PM systems even of less than V3.00. However, be careful of the possibility of unwanted signal loops, etc.

Notices for usage

  • An error dialog “Console Network ring connection open! Check cable connection.” may rarely be displayed when the sampling rate is changed on the WORD CLOCK screen. However, it does not affect the actual operation.
  • When INPUT patching is performed with the maximum number of channels of the HY256-TL or HY256-TL-SMF card exceeding 256, it appears to be correctly patched but no patch is established and no audio is input.
  • No tally signal is output from a fader moved by MIDI control change.
  • In rare cases, a “DSP Disconnected!” message could be shown. If the message appears, take the following course of action:
    1. Re-Sync manually. Check this first for the fastest possible recovery (Doesn’t apply to RIVAGE PM7).
    2. If that doesn’t solve the problem, use the [RESET] button on the back of the console (Operations 1 and 2 do not mute the audio).
    3. If that doesn’t solve the problem, restart the console.
    4. If that doesn’t solve the problem, restart the DSP Engine (Doesn’t apply to RIVAGE PM7) (Operations 3 and 4 mute the audio).
  • If you recall a Scene in which a very high HA gain was set, from a scene having a low HA gain, even if no signal is patched, a very loud pink noise signal is occasionally output for a few seconds.
  • When a certain type of USB keyboard is connected to the console, the following message may appear:
    You must restart your computer to apply these changes [Restart Now] [Restart Later]
    If this message is shown, remove this USB keyboard. It is not compatible with the console and cannot be used. The console does not need to be restarted.
  • When a DSP mirroring failover occurs, if the DSP engine B is set to active, the Word Clock master will not change automatically. To prevent audio dropouts, do not turn off the power of the DSP engine A even after a failover occurs.
  • The channel name LCD cannot display unsupported characters such as Japanese kanji used in the Dante channel labels.
  • If a DSP engine hosts one or more Dante cards (HY144-D and HY144-D-SRC in Synchronous (144io Sync SRC) mode), only check the “Enable Sync to External” option for the card that operates as the master on the Dante network.

注意

使用此軟體前,請仔細閱讀軟體授權協議(「協議」)。您僅可依據此協議的條款和條件使用此軟體。此為您(個人或法律實體)和 YAMAHA CORPORATION(「YAMAHA」)間簽署的協議。 

下載或安裝此軟體或以其他方式供您使用,您同意接受此授權條款的約束。如果您不同意此條款,請勿下載、安裝、複製或以其他方式使用此軟體。如果您下載或安裝軟體但不同意條款,請立即刪除軟體。

授權授予和版權

Yamaha 特此授予您依據隨附條款和條件,在您擁有或管理的電腦、樂器或設備上使用程式和隨附此協議並構成軟體一部分的資料檔案,以及未來可能提供您進行軟體升級的任何程式和檔案(統稱「軟體」)的權利。雖然儲存軟體的所有權為您所有,但該軟體本身屬於 Yamaha 和/或 Yamaha 的授權方所有,並受相關版權法和所有適用法規的保護。

限制

  • 您不得 從事反向工程、反彙編、反編譯或以任何方式取得軟體任何形式的程式碼。
  • 您不得 重製、修改、變更、租賃、出租或散布完整或部分軟體,以製作軟體的衍生品。
  • 您不得 以電子方式,從一台電腦傳輸軟體至另一台電腦,或在網路上與其他電腦共用軟體。
  • 您不得 使用軟體,散布非法資料或違反公共政策的資料。
  • 在未取得 Yamaha Corporation 的同意時,您不得依據軟體的使用,啟動服務。

透過軟體方式取得的版權保護資料,包含但不限於樂曲 MIDI 資料,有您必須遵守的以下限制條款。

  • 在未取得版權所有人的同意時,不得將透過軟體方式接收的資料作為商業用途使用。
  • 在未取得版權所有人的同意時,不得複製、傳輸或散布或為公開聽眾播放或表演透過軟體方式接收的資料。
  • 在未取得版權所有人的同意時,不得移除透過軟體方式接收資料的加密,且不得修改電子浮水印。

終止

如果違反版權法或此協議條款,協議將自動立即終止,Yamaha 恕不通知。如果以此方式終止,您必須立即銷毀授權的軟體、隨附的書面文件和所有副本。

下載的軟體

如果您認為下載流程有問題,可聯絡 Yamaha,Yamaha 可允許您重新下載該軟體,前提是您需先銷毀透過先前下載嘗試取得的軟體的任何副本或部分副本。重新下載的許可不得以任何方式限制以下第 5 節所述保固聲明。

軟體保固聲明

您明示已同意自負使用軟體的風險。軟體和相關文件以「原狀」提供,且無任何保固。儘管本協議另行規定,YAMAHA 明示放棄軟體的所有明示和暗示保固,包括但不限於對適銷性、特定用途的適用性和不侵犯第三方權利的暗示保固。特別是,但不限制上述規定,YAMAHA 不保證軟體滿足您的要求、軟體的操作不會中斷或沒有錯誤或軟體的缺失得以修正。

責任限制

YAMAHA 的全部義務是根據以下條款允許使用本軟體。在任何情況下,對您或任何其他人遭受的任何損害,包括但不限於任何直接、間接、偶然或間接損害、費用、利潤損失、資料遺失或其他因使用而造成的損害、誤用或無法使用該軟體,即使 YAMAHA 或授權經銷商已被告知此類損害的可能性,YAMAHA 概不負責。在任何情況下,Yamaha 對您的所有損害、損失和訴訟原因(無論是合約、侵權或其他方式)的全部責任均不超過為該軟體支付的金額。

第三方軟體

此軟體隨附第三方軟體和資料(「第三方軟體」)。如果軟體隨附的書面材料或電子資料中,Yamaha 將任何軟體和資料標示為第三方軟體,則您確認並同意您必須遵守第三方軟體隨附的任何協議條款以及提供第三方軟體的一方,對與第三方軟體相關或由第三方軟體衍生的任何保證或責任負責。因第三方軟體或使用,Yamaha 概不以任何方式負責。

  • Yamaha 不提供第三方軟體的明示保固。此外,對於第三方軟體,YAMAHA 明示放棄所有暗示保固,包括但不限於對適銷性和特定用途的適用性的暗示保固。
  • Yamaha 不應提供您第三方軟體的相關服務或維護。
  • 對您或任何其他人的任何損害,包括但不限於因使用、誤用或無法使用第三方軟體而導致的任何直接、間接、偶然或後果性損害、費用、利潤損失、資料遺失或其他損害,對您或任何其他人,Yamaha 概不負責。

美國政府限制權利通知:

該軟體是「商業項目」,該術語的定義可見 48 C.F.R. 2.101(1995 年 10 月),由「商業電腦軟體」和「商業電腦軟體文件」組成,這些術語在 48 C.F.R. 12.212 使用(1995 年 9 月)。與 48 C.F.R.一致的 12.212 和 48 C.F.R. 227.7202-1 至 227.72024(1995 年 6 月),所有美國政府最終使用者均應僅以此處規定的權利取得本軟體。

總則

此協議應根據日本法律解釋,不受法律衝突原則的約束。任何爭議或訴訟程序應在日本東京地方法院審理。如果因任何原因,具司法管轄權的法院認定本協議的任何部分無法執行,則本協議的其餘部分仍將維持其完整效力。

完整協議

本協議構成雙方間有關軟體使用和任何隨附書面材料的完整協議,並取代所有先前或同時就本協議達成的書面或口頭理解或協議。除非經 Yamaha 的完全授權代表書面簽字,否則本協議的任何修訂或修正均不具有約束力。


您還需要