QL5 Firmware V4.02 (Previous version)

Important notices of bugs

We found a serious bug with EQ-1A in Premium Rack, that might rarely cause a noise when operating the LO BOOST parameter, and a mute under certain conditions. We apologize for any inconvenience, and suggest to refrain from using EQ-1A until the fixed version is released. 
We identified another problem in which the CL/QL console might lose the HA control of Tio1608-D. We suggest to refrain from using Ti1608-D until the fixed version is released.

We identified a bug with V4.00 firmware, in which, under certain conditions, fader values would not be changed when the faders are moved manually. We already fixed it with V4.01, and highly recommend you to update the firmware from V4.00. 
In addition, we found another bug with V4.00 and V4.01, that could occur when connecting Shure ULXD receivers, and could change the GROUP/CH indication to unassigned on the receiver LCD and disconnect the wireless if operated over the P51 band (Germany and China only). We have released the bug-fix firmware V4.02 and advise you to update the firmware to V4.02 especially if using Shure ULXD over the P51 band.

Use this file to update QL5/1 to V4.02. Please read the following instructions before updating

Caution when updating

  • Use the "ql*_firm402.zip" (* is the model number) when updating.
  • Copy file "MQLP4_02.PGM" to the root directory of the USB memory. Follow the instructions on the update guide.
  • You need to update the Dante firmware if you update the QL firmware to V4.02 from V1.08 or older. You can now update the Dante firmware for QL also by using the USB memory. This method allows you to update both the firmware and the "MQLP4_02.PGM" file together at the same time.

*NOTE*

  • Before copying files, delete all files with extension .PGM and .BIN if any exists in the root directory of the USB memory. Prior to V3.0, the CL and QL Series used different files when updating, but both files used the same name * "C-MD1.BIN." For this reason, an error may occur during update when the incorrect "C-MD1.BIN" file is used or left in the root directory, and the TOUCH AND TURN knob will become inoperable. In order to recover from this mistake, copy the downloaded QL firmware file "QL-MD103.BIN" in the directory (\ql*_firm401\NAME SUB (* is the model number)) to the root directory of the USB memory. Follow the instructions on the update guide.
  • Updating Dante firmware by using a USB memory takes approximately 10 minutes.

Important notice of bug with EQ-1A

We found a serious bug with EQ-1A in Premium Rack, that might rarely cause a noise when operating the LO BOOST parameter, and a mute under certain conditions. We apologize for any inconvenience, and suggest to refrain from using EQ-1A until the fixed version is released.

Please do not use the EEE function (*) of network switches in a Dante network.

Although power management should be negotiated automatically in switches that support EEE, some switches do not perform the negotiation properly. This may cause EEE to be enabled in Dante networks when it is not appropriate, resulting in poor synchronization performance and occasional dropouts.

Therefore we strongly recommend that:
  • 1. If you use managed switches, ensure that they allow EEE to be disabled. Make sure that EEE is disabled on all ports used for real-time Dante traffic.
  • 2. If you use unmanaged switches, make sure to not use network switches that support EEE
  • * EEE (Energy Efficient Ethernet) is a technology that reduces switch power consumption during periods of low network traffic. It is also known as Green Ethernet and IEEE802.3az.

Cautions for Dante Firmware

  • You need to update the Dante-MY16-AUD firmware to V3.3.9 or later before using the Dante-MY16-AUD with the QL series.
  • The Dante Firmware Update Manager v1.4.13.2 for Mac does not support Mac OS X 10.6.8. 
    Please use Mac OS X 10.7.5, 10.8.5, 10.9.5, 10.10.x, or 10.11.x
  • The Dante Firmware Update Manager v1.4.16.6 for Windows does not support Windows XP. 
    Please use Windows 7, Windows 8/8.1, or Windows 10.
  • We found a problem in which the Dante settings might not be properly initialized when the firmware is updated, which results in data inconsistency between the CL/QL console and the R series units. This might occur only when the Dante Latency was set to 0.25ms or 0.5ms. Therefore, after updating, it is recommend to briefly change the Latency to 1.0ms on the console with the Console ID #1, then restore the original setting again. This will remove the possible data inconsistency between the console and the mounted R series units. However, Dante Controller will be needed to manually change the settings of R series units that are not mounted on the console with Console ID #1.

CL/QL/RIVAGE/R/Tio Series Editor/Firmware/R Remote Compatibility

Please make sure to use appropriate version of CL Editor or QL Editor which is compatible with your console firmware in reference to the following compatibility chart. Using an unsupported Editor/firmware combination may result in unexpected behavior.
The Firmware Set is a set of main (and sub) firmware of the device and the Dante firmware. The version of Firmware Set is the same as the version of the main firmware. Refer to the release note of each firmware about the details of the Firmware Set.

Compatibility List

  • You can use the following amount of CL/QL/R Remote units to remotely control each device unit (listed at left). 

    RSio64-D/Tio1608-D: Maximum of two CL/QL/R Remote units 
    RMio64-D: Maximum of six CL/QL/R Remote units 
    Rio/Ri/Ro: Maximum of four CL/QL units plus two separate computers operating R Remote.
  • You can connect maximum of ten iOS devices operating MonitorMix.

New Features in V4.00

  • Added new “Precise,” “Aggressive,” and “Smooth” Channel EQ algorithms.
  • Added new “MBC4” (multiband compressor) Premium Rack device.
  • Now supports controlling and monitoring for Shure ULXD4D and ULXD4Q Digital Wireless Receivers.
  • Added the Solo Mode (solo in place) to control input and output solo functions via the CUE keys.
  • Added the Second Cue Bus function which allows the MATRIX 7/8 bus to be used as a CUE B bus.
  • Now supports the “MonitorMix” iPhone application which allows wireless control of send levels to the mix bus. Up to ten devices running MonitorMix can be used simultaneously.
  • Now supports GEQ gain control from the TOUCH AND TURN knobs.
  • Now supports the Tio1608-D I/O Rack head amp control.
  • The COMPRESSOR and the EXPANDER of the DYNAMICS1 now support Key in Filter.
  • Added the MUTE GROUP ASSIGN, BUS SETUP, and SURROUND SETUP options to the FOCUS RECALL/RECALL SAFE/GLOBAL PASTE. Also added the LR nominal setting of each input channel to the TO ST as a target parameter.
  • Now the MASTER channel of the FADER BANK A now supports the custom fader function.
  • Added AVIOM D400 and Yamaha MRX7-D to the supported Dante devices.

Improvements in V4.00

  • The version number, when the memorized contents of each category correspond to that version’s specifications, is shown in the FILE LOAD function.
  • You can now stack the OUT and DCA IN with LAST CUE, just as with the MIX CUE.

Fixed bugs in V4.00

  • Solved a problem in which the SCENE 000 data was transferred via MIDI when recalling a Library of the Buss Comp 369.
  • Solved a problem in which, when performing Ch Move for a channel which is a member of a Ch Link, the channel parameters might (in some cases) be altered according to Ch Link A settings, rather than maintaining the correct settings of the channel.

Fixed bugs in V4.01

  • Solved a problem in which, under certain conditions, fader values would not be changed when the faders were moved manually.
  • Solved a problem in which V4.00 console was not able to load the data which had been made on the QL V1.0x or CL V1.70/V2.0x, and would show the warning message "Out of Range".

Fixed bugs in V4.02

  • Solved the following problems that would occur when connecting Shure ULXD receivers.
    • When connecting, depending on the used band (P51, R51, and Q51), the GROUP/CH indication would be changed to unassigned on the receiver LCD.
    • When connecting, the wireless frequency would be changed if operated over the P51 band (Germany and China only) within 710 - 770 MHz, which resulted in the wireless disconnection.
  • Solved a problem that would not correctly recall the DCA fader positions if recalling the scenes in which the Focus was off and the DCA Level/On was set to off.

Known issue

  • When an RSio64-D is not mounted, loading a console file which includes the information for mounting with an RSio64-D would cause initialization of the user patching. The problem occurs because the console could not get the device information properly.
  • If Dante Virtual Soundcard (DVS) is patched to the QL series device using Dante Controller, the patching may not be recalled correctly when the QL series device is restarted. Patch DVS again. In addition, when using a version of DVS for Windows that is older than v3.2.0, the patch after CH41 cannot be performed from QL series consoles.

NOTICE

  • When setting up the latency in Dante Controller, and there is a discrepancy in latency with the transmit device or the receive device, the largest (slowest) latency setting becomes effective.
  • The following device labels are used for detecting a SUPPORTED DEVICE.
    Y###-**********
    # is a three-digit hexadecimal number containing the digits 0 - 9 and uppercase A - F (000 - FFF)
    indicates any desired character (alphabetical uppercase or lowercase, numerals, or -(hyphen) may be used)
    Up to 31 characters including the 'Y' are supported.
    For the R-series, make sure that the ID indicated by Y###- is not duplicated by any other R-series unit.
  • In the QL firmware V1.08 or later, you can remotely control the internal HA of a QL series by using the Port to Port function, from additional QL series or CL series (firmware V2.03 or later) consoles, but be aware of the following restrictions:
    - In the case of QL5, you can remotely control the internal HA from external consoles only when Input 1-32 are patched to Dante Output 33-64 respectively, using the Port to Port functionality (default settings). Likewise, in case of QL1, it works only when Input 1-16 are patched to Dante Output 17-32 (the default patching needs to be changed).
    - If the HA channel is incorrectly patched from the QL console, through Dante, to the other console, the A.GAIN knob display of the corresponding channel will disappear. In that case, please check the patch settings including Port to Port.
  • Custom fader bank settings are not only included in user settings, but in scene data as well. The custom fader bank settings that are recalled vary depending on the logged-in user, the type of the loaded data, and the version. Please note the following points:
    - If you load console data of the ALL type as Administrator, the custom fader bank settings for the saved Administrator are recalled. If you load ALL data as Guest or another user, the custom fader bank settings for the saved current scene are called up.
    - If you load ALL data that was saved in CL V1.70 or earlier, since scenes do not include custom fader bank settings, the custom fader bank settings for the current scene when the load was performed are applied to all scenes. Therefore, before loading ALL data, we recommend that you either change users to set the custom fader bank to the desired setting, or that you enable Recall Safe for the custom fader bank.
  • File Converter V3.0.0, compatible with CL firmware V2.00, V3 and V4.00, and QL firmware V3 and V4.00, has been made available for use.

注意

使用此軟體前,請仔細閱讀軟體授權協議(「協議」)。您僅可依據此協議的條款和條件使用此軟體。此為您(個人或法律實體)和 YAMAHA CORPORATION(「YAMAHA」)間簽署的協議。 

下載或安裝此軟體或以其他方式供您使用,您同意接受此授權條款的約束。如果您不同意此條款,請勿下載、安裝、複製或以其他方式使用此軟體。如果您下載或安裝軟體但不同意條款,請立即刪除軟體。

授權授予和版權

Yamaha 特此授予您依據隨附條款和條件,在您擁有或管理的電腦、樂器或設備上使用程式和隨附此協議並構成軟體一部分的資料檔案,以及未來可能提供您進行軟體升級的任何程式和檔案(統稱「軟體」)的權利。雖然儲存軟體的所有權為您所有,但該軟體本身屬於 Yamaha 和/或 Yamaha 的授權方所有,並受相關版權法和所有適用法規的保護。

限制

  • 您不得 從事反向工程、反彙編、反編譯或以任何方式取得軟體任何形式的程式碼。
  • 您不得 重製、修改、變更、租賃、出租或散布完整或部分軟體,以製作軟體的衍生品。
  • 您不得 以電子方式,從一台電腦傳輸軟體至另一台電腦,或在網路上與其他電腦共用軟體。
  • 您不得 使用軟體,散布非法資料或違反公共政策的資料。
  • 在未取得 Yamaha Corporation 的同意時,您不得依據軟體的使用,啟動服務。

透過軟體方式取得的版權保護資料,包含但不限於樂曲 MIDI 資料,有您必須遵守的以下限制條款。

  • 在未取得版權所有人的同意時,不得將透過軟體方式接收的資料作為商業用途使用。
  • 在未取得版權所有人的同意時,不得複製、傳輸或散布或為公開聽眾播放或表演透過軟體方式接收的資料。
  • 在未取得版權所有人的同意時,不得移除透過軟體方式接收資料的加密,且不得修改電子浮水印。

終止

如果違反版權法或此協議條款,協議將自動立即終止,Yamaha 恕不通知。如果以此方式終止,您必須立即銷毀授權的軟體、隨附的書面文件和所有副本。

下載的軟體

如果您認為下載流程有問題,可聯絡 Yamaha,Yamaha 可允許您重新下載該軟體,前提是您需先銷毀透過先前下載嘗試取得的軟體的任何副本或部分副本。重新下載的許可不得以任何方式限制以下第 5 節所述保固聲明。

軟體保固聲明

您明示已同意自負使用軟體的風險。軟體和相關文件以「原狀」提供,且無任何保固。儘管本協議另行規定,YAMAHA 明示放棄軟體的所有明示和暗示保固,包括但不限於對適銷性、特定用途的適用性和不侵犯第三方權利的暗示保固。特別是,但不限制上述規定,YAMAHA 不保證軟體滿足您的要求、軟體的操作不會中斷或沒有錯誤或軟體的缺失得以修正。

責任限制

YAMAHA 的全部義務是根據以下條款允許使用本軟體。在任何情況下,對您或任何其他人遭受的任何損害,包括但不限於任何直接、間接、偶然或間接損害、費用、利潤損失、資料遺失或其他因使用而造成的損害、誤用或無法使用該軟體,即使 YAMAHA 或授權經銷商已被告知此類損害的可能性,YAMAHA 概不負責。在任何情況下,Yamaha 對您的所有損害、損失和訴訟原因(無論是合約、侵權或其他方式)的全部責任均不超過為該軟體支付的金額。

第三方軟體

此軟體隨附第三方軟體和資料(「第三方軟體」)。如果軟體隨附的書面材料或電子資料中,Yamaha 將任何軟體和資料標示為第三方軟體,則您確認並同意您必須遵守第三方軟體隨附的任何協議條款以及提供第三方軟體的一方,對與第三方軟體相關或由第三方軟體衍生的任何保證或責任負責。因第三方軟體或使用,Yamaha 概不以任何方式負責。

  • Yamaha 不提供第三方軟體的明示保固。此外,對於第三方軟體,YAMAHA 明示放棄所有暗示保固,包括但不限於對適銷性和特定用途的適用性的暗示保固。
  • Yamaha 不應提供您第三方軟體的相關服務或維護。
  • 對您或任何其他人的任何損害,包括但不限於因使用、誤用或無法使用第三方軟體而導致的任何直接、間接、偶然或後果性損害、費用、利潤損失、資料遺失或其他損害,對您或任何其他人,Yamaha 概不負責。

美國政府限制權利通知:

該軟體是「商業項目」,該術語的定義可見 48 C.F.R. 2.101(1995 年 10 月),由「商業電腦軟體」和「商業電腦軟體文件」組成,這些術語在 48 C.F.R. 12.212 使用(1995 年 9 月)。與 48 C.F.R.一致的 12.212 和 48 C.F.R. 227.7202-1 至 227.72024(1995 年 6 月),所有美國政府最終使用者均應僅以此處規定的權利取得本軟體。

總則

此協議應根據日本法律解釋,不受法律衝突原則的約束。任何爭議或訴訟程序應在日本東京地方法院審理。如果因任何原因,具司法管轄權的法院認定本協議的任何部分無法執行,則本協議的其餘部分仍將維持其完整效力。

完整協議

本協議構成雙方間有關軟體使用和任何隨附書面材料的完整協議,並取代所有先前或同時就本協議達成的書面或口頭理解或協議。除非經 Yamaha 的完全授權代表書面簽字,否則本協議的任何修訂或修正均不具有約束力。